Product Details:
|
Item Name: | Red Cap Clot Activator Tube, Vacuum Type, PET Tube, 13mm*75mm | Classification: | Coagulation Tube |
---|---|---|---|
Category: | Serum Blood Collection Tube | Cap Color: | Red |
Label: | Paper Or UV Printing | Volume: | 2ml |
Additive: | Clot Activator | Shelf Life: | 1 Year |
HS Code: | 9018390000 | Min. Clotting Time: | 30 Minutes |
High Light: | Pro Coagulation Vacuum Blood Collection Tube,Clot Activator Vacuum Blood Collection Tube |
Red Cap Clot Activator Tube, Vacuum Type, PET Tube, 13mm*75mm
【Clot Activator Tube Function】
Clot activator is precisely dispensed in the vacuum blood collection tube. The pro-coagulation tube is used for blood collection and storage for biochemistry, immunology, element trace, various types of virus detection and so on for clinical tests. Invert 5-6 times after blood collection, and wait for 30 minutes before centrifuge.
【Clot Activator Tube Specifications】
Items | Clot Activator Tube |
Classification | Coagulation Tube |
Category | Serum Blood Collection Tube |
Cap Color | |
Additive | Clot Activator |
Material | Glass/PET |
Size (Volume) | 13mm*75mm (2ml, 3ml, 4ml), 13mm*100mm (5ml, 6ml), 16mm*100mm (7ml, 8ml, 9ml, 10ml) |
Precautions for Use | Immediately after blood collection, invert and mix 6-8 times, it is recommended to stand for 30 minutes, and centrifuge only when light yellow serum is precipitated |
Centrifugal Standard
|
Recommended centrifugal force ≦1300g, 10 minutes |
Storage Temperature | 4-25℃ |
Applicable Tests | Clinical biochemistry, immunology and serology test |
【Clot Activator Tube Use Instruction】
Step 1: Choose the right specification pen-type blood collection needle and take off the white cover of the vacutainer needle.
Step 2: Screw the tube needle into the needle holder.
Step 3: Take off the color cover of the needle and choose the human proper vein to puncture. Insert the vacuum blood collection tube into the holder and press to puncture the tube stopper.
Step 4: After the vacuum in the tube used up, blood will stop flowing into the tube. Take out the vacutainer tube from the holder.
Step 5: Right after the blood tube taken out, turn it upside down 5-6 times to mix the blood and additive inside completely. Intense turning is strictly prohibited.
Step1: Screw tight the connection between tube needle and the soft pipe to prevent leakage of vacuum or blood during the blood collection.
Step 2: Choose the human proper vein to puncture and blood flow could be seen.
Step 3: Insert another side of the venous blood collection needle into the tube stopper.
Step 4: When 0.5ml short of the rated blood volume in the final tube, take out the needle from the vein. Take off the needle from tube after blood in the soft pipe all flows into the blood draw tube.
Step 5: Right after the vacutainer needle taken out, turn the blood sampling tube upside down 5-6 times to mix the blood and additive inside completely. Intense turning is strictly prohibited.
【Clot Activator Tube Related Product】
ACD Tube - Special Use Blood Collection Tube
【Clot Activator Tube FAQ】
1. What are the right sequence and attentions of blood collection?
The sequence is showed as below, the attentions are:
Ⅰ. It’s critical to fix the needle holder and needle wing of the scalp vein set.
Ⅱ. Do not use the tourniquet more than 1 minute.
Ⅲ. Immediately mix the blood and additive inside the tube after blood collection.
Ⅳ. Collect blood as left sequence.
2. What are the right steps of correctly preparing high quality serum with Gel/Clot activator tube.