Product Details:
|
Item Name: | Black Top ESR Tube With Additive Of 3.8% Sodium Cirtrate (0.129mol/L) | Cap: | Black |
---|---|---|---|
Additive: | 3.8% Sodium Cirtrate (0.129mol/L) | Tube Material: | PET/Glass |
Label: | Paper/Transparent/UV Printing | Tube Size: | 13*75mm, 8*120mm |
Volume: | 1.28ml, 1.6ml, 2.0ml, 2.4ml, 3ml | Shelf Life: | 2 Years (Glass), 1 Year (PET) |
Category: | Whole Blood Collection Tube | Classification: | ESR Tube |
Highlight: | 0.129mol/L ESR Tube,3.8% Sodium Cirtrate ESR Tube,Black Top ESR Tube |
Black Top ESR Tube with Additive of 3.8% Sodium Cirtrate (0.129mol/L)
【ESR Tube Introduction】
13×75mm ESR test tube is specially used in blood collection and anticoagulation for Automated Erythrocyte Sedimentation Rate Analyzers sedimentation rate test with the mixing ratio of 1 part sodium citrate to 4 parts blood, by Westergren method.
8×120mm ESR sample tube is applicable to various Automated Erythrocyte Sedimentation Rate Analyzers. Due to little volume and negative pressure inside the tube, it needs some time for blood collection. Do patiently wait until blood stops flowing into the tube, then completely mix the anticoagulation and additive by turning the tube upside down for 6-8 times. Inappropriate mixing will cause hemolysis, coagulation or blood bubble and influence the test result.
【ESR Tube Categories】
Category | Type | Additive | Cap Color | Tube Material | Tube Size | Test Item |
Serum Blood Collection Tube | Plain Tube | Plain | Glass/Plastic | 13*75mm | Clinical Biochemistry, Immunology and Serology Test |
|
13*100mm | ||||||
16*100mm | ||||||
Pro-coagulation Tube | Clot Activator | Glass/Plastic | 13*75mm | |||
13*100mm | ||||||
16*100mm | ||||||
Gel & Clot Activator Tube | Gel & Coagulant | Glass/Plastic | 13*75mm | |||
13*100mm | ||||||
16*100mm | ||||||
Whole Blood Collection Tube | EDTA Tube | Sprayed K2EDTA / K3EDTA | Glass/Plastic | 13*75mm | Haematology Test (Blood Routine Examination) |
|
13*100mm | ||||||
16*100mm | ||||||
ESR Tube | 3.8% Sodium Citrate Buffer (0.129mol/L), 3.2% Sodium Citrate Buffer (0.109mol/L) | Glass/Plastic | 13*75mm | Erythrocyte Sedimentation Rate Test |
||
13*100mm | ||||||
16*100mm | ||||||
Plasma Blood Collection Tube | Coagulation Tube |
3.2% Sodium Citrate Buffer (0.109mol/L) |
Glass/Plastic | 13*75mm | Coagulation Function Test | |
13*100mm | ||||||
16*100mm | ||||||
Heparin Tube |
Sodium Heparin / Lithium Heparin |
Glass/Plastic | 13*75mm | Clinical Biochamistry for Emergency Treatment, Blood Rheology Test | ||
13*100mm | ||||||
16*100mm | ||||||
Glucose Tube | Sodium Fluoride & EDTA K2 / Sodium Fluoride & EDTA Na2 | Glass/Plastic | 13*75mm | Blood Glucose and Lactate Test |
||
13*100mm | ||||||
16*100mm |
【ESR Tube Sequence】
Attentions:
【ESR Tube Use Instructions】
Step 1: Choose the right specification pen-type blood collection needle and take off the white cover of the vacutainer needle.
Step 2: Screw the tube needle into the needle holder.
Step 3: Take off the color cover of the needle and choose the human proper vein to puncture. Insert the ESR tube Westergren into the holder and press to puncture the tube stopper.
Step 4: After the vacuum in the tube used up, blood will stop flowing into the tube. Take out the ESR Westergren tube from the holder.
Step 5: Right after the blood tube taken out, turn it upside down 5-6 times to mix the blood and additive inside completely. Intense turning is strictly prohibited.
Step1: Screw tight the connection between tube needle and the soft pipe to prevent leakage of vacuum or blood during the blood collection.
Step 2: Choose the human proper vein to puncture and blood flow could be seen.
Step 3: Insert another side of the venous blood collection needle into the tube stopper.
Step 4: When 0.5ml short of the rated blood volume in the final tube, take out the needle from the vein. Take off the needle from Westergren tube after blood in the soft pipe all flows into the blood draw tube.
Step 5: Right after the vacutainer needle taken out, turn the blood sampling tube upside down 5-6 times to mix the blood and additive inside completely. Intense turning is strictly prohibited.
Remark: The steps of correctly preparing high quality serum with Gel/Clot activator tube.
【ESR Tube Related Products】
Venous Blood Collection Needle
Non-Vacuum Blood Collection Tubes
Mini Blood Collection Tube
Contact Person: Cage Wan
Tel: 86-18550761548 / 86-18501567726